link:: www.westernloggroup.com

     
 

Wildfowl and Wetlands Trust HQ. Slimbridge, Glos.

The main contractor of The Wetlands Trust HQ approached CIS to access our knowledge on Intumescent Coatings, to provide Class O Surface Spread of Flame (BS476 Part 6 1987) to the ashed faced boarding in their new Head Quarters.
After research and consultation we advised them that the solution was to use Envirograf ES/VFR Intumescent Clear Coating System, which is not affected by moisture or other environmental problems, and is the ideal system for the use on Hard Faced Boards.

 

Brasenose College, Oxford

The college architect approached CIS after previous installation problems, as a valued consultant to advise them on upgrading of various flat, raised and fielded panel doors, on various staircases.
The approved specification was to apply Envirograf ES/MP/FC Intumescent Fire Card, to flat panel doors and Envirograf ES/RFC Coating System to raised and fielded panel doors. The benefits of these two systems was to provide the required 30 minutes fire integrity (BSA76 Part 22 1987) and still maintain the features.
Not only did CIS provide the specification but we were also able to offer our Specialist Application Service which included the fitting of Intumescent Fire and Smoke Seals and Hinge Protection. Therefore insuring peace of mind as we were able to produce Full Fire Certification upon completion.

 

Cote House, Westbury-on-Trym, Bristol.

CIS were called into site by the architect to investigate the use of a suitable Intumescent providing Class 0 surface spread of flame to existing varnished decorative timber surfaces, in the hallway and the staircase areas of this period property.
After a inspection of the property by CIS the product most suitable for the work to be carried out was Envirograf ES/VFR were the top protective coating was tinted mahogany to ensure clarity of existing timbers.
CIS where then able to call upon their preferred sub contractors to carry out this specialist work.

 

Museum in the Park, Stratford Park, Stroud

We were approached by Moss Construction of Cheltenham not only to advise how to give Fire Protection to existing lathe and plaster ceiling, but also on panel doors within this period property. They also wanted a company with specialist knowledge to this in accordance with the building regulations and BS standards.
We were able to supply and install Envirograf UF60 Under floor Fire Barrier System between the joist to achieve 60 minutes fire integrity, insulation and load bearing to BS476 Part 21 1987. Therefore not affecting the existing lathe and plaster below. The benefits of using UF60 system is lightweight fibre free and quick to install.

 

Sub-Tone Cafe, Promenade, Cheltenham, Glos.

CIS were called upon to investigate to provide 60 minute Fire Integrity to a decorative lathe and plaster ceiling.
We couldn't provide protection between the joists because the premises above where in constant use. The solution we provided was to apply Envirograf S/Ceramic Intumescent Paper System bonded to the ceiling using CA/N adhesive and EP/CP Plaster Board Coating to the decorative coving and ceiling rose
This system not only provided the necassary fire protection but also gave 60 minute insulation and load bearing to BS476 Part 21.
We also advised the contract decorators how to apply the system to the decorative finishes.

 

Royal Glamorgan Hospital, Llantrisant, South Wales (New Build)

After a long working relationship with the hospitals architects Capita, CIS worked in conjunction with them to provide our expertise and specialist consultation services for the new build of the hospital.
We were able to provide not only Intumescent Fire Tents and Down Lighter Covers to recessed light fittings, but also to pipes and services passing through fire rated partitions in the plant room. One problem we faced was that many of the pipes were fixed closly together and indivdual fire protection was not possible. The solution was to provide Envirograf EB Intumescent Boxes to acheive 60 minute fire integrity to BS476 Part 20 +22 1987, some of which was manufactured specially to fit 2 or 3 pipes.

 